Weiss Climate Test Chamber WK3-600/0-M, 600 liters, with humidity control, temperature range -5°C toWeiss
Klimaprüfschrank
Weiss Climate Test Chamber WK3-600/0-M, 600 liters, with humidity control, temperature range -5°C to
Weiss
Klimaprüfschrank
État
Occasion
Emplacement
Borken 

Données de base
- Désignation de la machine:
- Weiss Climate Test Chamber WK3-600/0-M, 600 liters, with humidity control, temperature range -5°C to
- Fabricant:
- Weiss
- Modèle:
- Klimaprüfschrank
- État:
- d'occasion
Prix et localisation
- Emplacement:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Appel
Détails sur l'offre
- Identifiant de l'annonce:
- A222-70542
- Numéro de référence:
- 24892
- Mise à jour:
- dernière mise à jour le 15.10.2026
Description
Weiss
Type: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Type series WK3-../0
with SIMPAC* control system
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Data for operation:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Fuse (on customer's side): 16 A, slow-blow
Protection class, control cabinet and operating panel: IP 54
Max. heat dissipation to environment: 1200 W
Sound pressure level approx.
measured at a distance of 1 m from the front, 1.6 m high: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient
(according to IEC 60068-3-5)
Temperature change rate
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation at +20 °C to +50 °C: 200 W
Data for climate tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.3 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Humidity deviation over time: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Blodpfx Aboziywrofsp
We will gladly answer any further questions you may have by telephone.
L'annonce a été traduite automatiquement et des erreurs de traduction peuvent apparaître.
Type: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Type series WK3-../0
with SIMPAC* control system
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Data for operation:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Fuse (on customer's side): 16 A, slow-blow
Protection class, control cabinet and operating panel: IP 54
Max. heat dissipation to environment: 1200 W
Sound pressure level approx.
measured at a distance of 1 m from the front, 1.6 m high: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient
(according to IEC 60068-3-5)
Temperature change rate
Heating: 0.6 K/min
Cooling: 0.3 K/min
Heat compensation at +20 °C to +50 °C: 200 W
Data for climate tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5 °C
Humidity range: 10 to 98 % RH
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.3 K
Temperature deviation spatially: ± 0.5 to ± 1 K
Humidity deviation over time: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
For your security as a buyer, please note the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers will be subjected to a test run, which will be monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
Blodpfx Aboziywrofsp
We will gladly answer any further questions you may have by telephone.
L'annonce a été traduite automatiquement et des erreurs de traduction peuvent apparaître.
Envoyer une demande
Téléphone & Fax
+49 2861 ... afficher
Ces annonces pourraient également vous intéresser.
Réussite :
Votre message a été envoyé.
Annonce
Borken
713 km
Weiss enceinte climatique avec régulation d'humidité, plage de température de -42°C à +180°C, capaci
WeissKlimaprüfschrank
WeissKlimaprüfschrank
Réussite :
Votre message a été envoyé.
Annonce
Borken
713 km
Weiss enceinte climatique WK3-340/70 avec contrôle d’humidité, plage de température de -72°C à +180°
WeissKlimaprüfschrank
WeissKlimaprüfschrank
Réussite :
Votre message a été envoyé.
Annonce
Borken
713 km
Chambre climatique Weiss WK1-1000/70 -70°C à 180°C avec humidité, capacité 990 litres
WeissKlimaprüfschrank WK1-1000/70
WeissKlimaprüfschrank WK1-1000/70
Réussite :
Votre message a été envoyé.
Annonce
Borken
713 km
Weiss enceinte climatique avec régulation d'humidité, plage de température de -42°C à +180°C, capaci
WeissKlimaprüfschrank
WeissKlimaprüfschrank
Réussite :
Votre message a été envoyé.
Annonce
Borken
713 km
Chambre climatique Weiss avec réglage d'humidité SB2/500/80 -75°C à +180°C
WeissKlima-Prüfschrank
WeissKlima-Prüfschrank
Votre annonce a été supprimée
Une erreur est survenue